The Cyclone Hot Water Boilers provide for exceptionally high efficiencies, lower fuel costs, and extremely rugged construction.
Other Features Include
- Compact space saving vertical design
- Four-Pass Design
- Shock Proof, no tubes to loosen or burn out
- Convenient access to “eye high” burner
- Solid State controls for trouble free operation
- Factory assembled, fully automatic
- UL and ASME CSD - 1
- Simple and inexpensive to install
- Standard design pressure of 30 PSI
- Optional to 160 PSI, 250° F

| CYCLONE SERIES SPECIFICATIONS |
| |
BOILER HORSEPOWER |
6 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
70 |
80 |
100 |
|
| |
GROSS OUTPUT |
(MBH), BTU X 1000 KCAL X 1000 |
201 51 |
335 84 |
502 127 |
670 169 |
837 211 |
1004 253 |
1339 337 |
1674 422 |
2009 506 |
2343 590 |
2678 675 |
3348 844 |
|
| INPUT REQUIRED |
BTU X 1000 KCAL X 1000 |
251 63.3 |
418 105 |
628 158 |
837 211 |
1046 264 |
1255 316 |
1674 422 |
2092 527 |
2511 633 |
2929 738 |
3348 844 |
4184 1054 |
| FIRING RATE, NAT. GAS 1000 BTU/FT3 |
FT 3/HR. M 3/HR. |
251 7.1 |
418 11.8 |
628 17.8 |
837 23.7 |
1046 29.6 |
1255 35.5 |
1674 47.4 |
2092 59.2 |
2511 71.1 |
2929 82.9 |
3348 94.8 |
4184 118.5 |
| FIRING RATE, LP. GAS 91,500 BTU/GAL. |
GPH LPH |
2.7 10.4 |
4.6 17.3 |
6.9 26 |
9.1 34.6 |
11.4 43.3 |
13.7 51.9 |
18.3 69.2 |
22.9 86.6 |
27.4 103.9 |
32 121.2 |
36.6 138.5 |
45.7 173.1 |
| FIRING RATE, No.2 oil 140.000 BTU/GAL. |
GPH LPH |
1.8 6.8 |
3 11.3 |
4.5 17 |
6 22.6 |
7.5 28.3 |
9 33.9 |
12 45.3 |
14.9 56.6 |
17.9 67.9 |
20.9 79.2 |
23.9 90.5 |
29.9 113.1 |
| A |
OUTLET SIZE |
IN. MM |
2 51 |
2 51 |
2 51 |
3 76 |
3 76 |
4 102 |
4 102 |
6 152 |
6 152 |
6 152 |
6 152 |
6 152 |
A |
| B |
RETURN SIZE |
IN. MM |
2 51 |
2 51 |
2 51 |
2.5 64 |
2.5 64 |
3 76 |
3 76 |
4 102 |
4 102 |
4 102 |
4 102 |
4 102 |
B |
| C |
DRAIN SIZE |
IN. MM |
1 25 |
1 25 |
1 25 |
1 25 |
1 25 |
1.25 32 |
1.25 32 |
1.25 32 |
1.25 32 |
1.5 38 |
1.5 38 |
1.5 38 |
C |
| D |
STACK DIA. |
IN. MM |
8 203 |
8 203 |
8 203 |
8 203 |
8 203 |
10 254 |
12 305 |
12 305 |
12 305 |
14 356 |
14 356 |
14 356 |
D |
| E |
STACK HEIGHT |
IN. MM |
52 1321 |
52 1321 |
58 1473 |
64 1626 |
64 1626 |
63 1600 |
73 1854 |
83 2108 |
83 2108 |
82 2083 |
82 2083 |
82 2083 |
E |
| F |
WIDTH WITHOUT TRIM |
IN. MM |
35.2 894 |
35.2 894 |
35.2 894 |
35.2 894 |
35.2 894 |
41 1041 |
50 1270 |
59 1499 |
59 1499 |
68 1727 |
68 1727 |
78.2 1986 |
F |
| G |
WIDTH WITH TRIM |
IN. MM |
42 1067 |
42 1067 |
42 1067 |
42 1067 |
42 1067 |
47 1194 |
55 1397 |
63 1600 |
63 1600 |
72 1829 |
72 1829 |
82 2083 |
G |
| H |
OVERALL HEIGHT |
IN. MM |
70 1778 |
70 1778 |
76 1930 |
82 2083 |
82 2083 |
82 2083 |
93 2362 |
105 2667 |
105 2667 |
106 2692 |
106 2692 |
106 2692 |
H |
| I |
HEIGHT WITHOUT TRIM |
IN. MM |
65 1651 |
65 1651 |
71 1803 |
77 1956 |
77 1956 |
77 1956 |
88 2235 |
98 2489 |
98 2489 |
98 2489 |
98 2489 |
98 2489 |
I |
| J |
LENGTH |
IN. MM |
60 1524 |
60 1524 |
60 1524 |
60 1524 |
60 1524 |
78 1981 |
87 2210 |
115 2921 |
115 2921 |
120 3048 |
120 3048 |
127 3226 |
J |
| |
WATER CAPACITY |
GALS. LITERS |
62 235 |
62 235 |
68 257 |
79 299 |
79 299 |
113 428 |
208 787 |
313 1185 |
313 1185 |
440 1665 |
440 1665 |
591 2237 |
|
| SHIPPING WEIGHT |
LBS. KG. |
1600 726 |
1600 726 |
1750 794 |
1800 816 |
1800 816 |
2175 987 |
3775 1712 |
5300 2404 |
5300 2404 |
7300 3311 |
7300 3311 |
8700 3946 |
| |
BOILER HORSEPOWER |
|
6 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
70 |
80 |
100 |
| |
| Outlet connection over four inches are 150# flanges. All other connections are NPT. We assume no responsibility for errors in data. Consult factory for certified drawings. |